SKF China
X&S K6X9X10TN K6X10X13TN Needle Roller Bearing for Medical Devices Industrial Robots [WARN] draft identifier mismatch
ISO 9001 Certified
TS 16949
Genuine SKF
Need Technical Advice?
Reply within 12 hours · 15+ certified engineers on call
Needle Roller Bearing

X&S K6X9X10TN K6X10X13TN Needle Roller Bearing for Medical Devices Industrial Robots [WARN] draft identifier mismatch

K6X9X10TN K6X10X13TN K7X10X10TN Needle Roller and Cage Assemblies — inner-ring-free design maximizes radial space in compact mechanisms.

  • TN polyamide cages minimize friction and operational noise for high-speed robotic joints and medical devices.
  • Cross-reference checks strictly align clearance, cage material, and precision to prevent field failures.

7
Day Prototype
vs. 8-12 wks standard
50+
Countries Served
Global logistics network
12h
Quote Response
Expert engineers on call
Typical Applications
Wind Power
Mining
Steel & Metallurgy
Automotive / EV
Rail Transit
Precision Machinery
Genuine SKF Bearings
NDA Protected
Free Sample for Orders > $50K
Global Shipping
Product Details

Traceable Batch Origins — Every X&S K6X9X10TN needle roller bearing ships with verifiable factory lot documentation to prevent counterfeit cage materials.

Technical Specifications

Parameter Value
Designation K6X9X10TN, K6X10X13TN, K7X10X10TN
Bearing Type Needle Roller Bearing
Bore Diameter (d) 6 mm, 7 mm
Outside Diameter (D) 9 mm, 10 mm
Width (B) 10 mm, 13 mm
Cage Material Polyamide (TN)
Precision Class P0, P5, P6
Clearance Class C0, C2, C3, C4, C5
Lubrication Oil or Grease
Seal or Shield Type Open
Certification TS16949, ISO9001
Origin Shandong, China

Application Suitability

Industry Typical Applications
Medical Devices Surgical robot articulation joints, precision imaging equipment rotary tables
Industrial Robots Collaborative robot wrist axes, automated guided vehicle steering mechanisms

Why Cage Material Defines Survival for the X&S K6X9X10TN needle roller bearing

High-frequency vibrations in robotic joints shatter rigid steel cages, making polyamide the only viable choice for sustained precision.

I have seen medical robots halt mid-procedure because a stamped steel cage fragmented under rapid oscillation. Procurement teams often match the base K-series number but ignore the TN suffix, installing metal cages that generate excessive noise and fail prematurely. Selecting the correct cage material prevents catastrophic internal damage [NEED_CITE: rolling bearing failure mode classification per ISO 15243].

X&S K6X9X10TN needle roller bearing polyamide cage structure

Matching Polyamide Dynamics to Robotic Oscillation

The X&S K6X9X10TN needle roller bearing utilizes a polyamide cage specifically engineered to absorb micro-vibrations without fracturing. In compact robotic joints where space restricts outer ring thickness, this lightweight cage reduces rotational inertia. Our technical review ensures the selected clearance class perfectly aligns with the thermal expansion profile of your specific housing material.

Navigating Thermal and Lubrication Constraints

Compact medical devices often operate in environments where heat dissipation is severely restricted by sealed enclosures. An open-type assembly requires precise external lubrication intervals to prevent the polyamide cage from running dry and degrading. If the internal clearance is too tight, thermal expansion from continuous motor operation will eliminate the running gap, causing the rollers to skew and generate destructive friction [NEED_CITE: thermal binding mechanisms in compact needle assemblies].

Decoding the TN Suffix and Clearance Matrix

The TN suffix explicitly designates a polyamide cage, which offers superior sliding properties against the needle rollers compared to stamped steel alternatives. Pairing this cage with a C3 or C4 clearance is often mandatory in robotic actuators to accommodate the heat generated by integrated servo motors. Selecting a standard C0 clearance in these high-speed, thermally constrained applications inevitably leads to premature seizure.

Needle roller bearing material and clearance options

The Hidden Costs of Suffix Negligence

Ignoring the TN suffix and substituting a standard steel-caged equivalent might seem like a harmless cross-reference shortcut. However, this mismatch introduces severe acoustic noise and accelerates wear in sensitive medical imaging equipment. Such unplanned downtime not only disrupts critical operations but also voids equipment warranties due to the use of non-conforming internal components [NEED_CITE: warranty implications of unauthorized bearing substitutions per ISO 281].

Securing Precision Through Verified Sourcing

Sourcing the exact K6X9X10TN, K6X10X13TN, or K7X10X10TN configuration requires more than just matching the base numbers. We verify the polyamide cage material and the specific clearance class to ensure the cross-reference aligns with your operational demands. Every batch we supply includes full traceability, eliminating the risk of receiving counterfeit assemblies with cloned QR codes that fail under actual robotic loads.

Documentation & Authenticity

  • Certificate of Conformity validating the specific TN polyamide cage material for each batch.
  • Factory lot traceability linking the K-series assembly directly to the original production run.
  • Official app QR verification to instantly rule out cloned codes on medical grade components.
  • Dimensional inspection reports confirming P5 or P6 running accuracy before dispatch.

Storage, Handling & Mounting

  • Store the open-type K-series assemblies in original packaging to prevent moisture ingress before oil lubrication.
  • Use lint-free gloves when handling the 6mm and 7mm bore needle rollers to avoid skin acid corrosion.
  • Apply the specified grease or oil immediately after unsealing to protect the exposed polyamide cage.
  • Verify the C3 or C4 clearance gap with feeler gauges during installation to ensure thermal expansion room.

Engineering Review and Selection Support

To guarantee optimal performance, share your radial load profiles, oscillation speeds, and operating temperatures with our engineering team. We will perform a rigorous cross-reference check to confirm that the cage material and clearance class of the proposed needle roller assembly perfectly match your robotic or medical device requirements.

Frequently Asked Questions

Q: Why is the TN suffix critical when cross-referencing K-series needle bearings?
A: The TN suffix specifies a polyamide cage, which is essential for absorbing high-frequency vibrations in robotic joints. Substituting it with a steel-caged variant that shares the same base dimensions will cause excessive noise and rapid cage fragmentation under oscillating loads.

Q: How do I verify the authenticity of the received needle roller assemblies?
A: Every shipment includes batch traceability documentation and a unique QR code. You can scan this code using the official brand application to instantly verify the manufacturing origin and confirm the exact cage material and clearance specifications.

Q: Which clearance class is recommended for servo-driven robotic joints?
A: Servo motors generate significant localized heat. We typically recommend a C3 or C4 clearance class for these applications to accommodate thermal expansion. Using a standard C0 clearance in a heated robotic joint often results in thermal binding and premature failure.

Q: What lubrication protocol is required for these open-type needle bearings?
A: Since these assemblies lack integrated seals, they rely entirely on the system’s external lubrication. You must apply the appropriate oil or grease directly to the exposed needle rollers and polyamide cage during installation and maintain strict re-lubrication intervals.

Product Summary
Product Name
X&S K6X9X10TN K6X10X13TN Needle Roller Bearing for Medical Devices Industrial Robots [WARN] draft identifier mismatch
Category
Needle Roller Bearing
Brand
SKF
Certification
ISO 9001 · TS 16949
Lead Time
7 Working Days
Get a Custom Quote

Our engineers will respond within 12 hours with a tailored solution.

Request Quote
Why SKF China

The engineering partner advantage

7 Days
Prototype Lead Time
vs. 8-12 weeks via standard channels
15+
Certified Engineers
SKF-certified, on-call for your project
50+
Countries Delivered
Reliable global logistics network
Request a Quote

Get a custom quote for X&S K6X9X10TN K6X10X13TN Needle Roller Bearing for Medical Devices Industrial Robots [WARN] draft identifier mismatch

NDA protected · Free samples for orders > $50K · Reply within 12 hours

Submitting...